B2B Shop | Compressed Air | Filtration | Technology
Shop 14 items found.

KAESER DHS 4.0 Pressure Maintenance System – Ensuring Compressed Air Quality

Choosing the Right Pressure Maintenance System for Your Compressed Air Station

A pressure-maintaining system protects refrigeration dryers and filters from overflow during restart after periods of downtime. The KAESER DHS 4.0 series includes models with ball valves (threaded connections from G 3/4" to G 2 1/2") and with intermediate flanges (flanged connections DN 50 to DN 150)—each featuring patented pulse width modulation and a SIGMA NETWORK interface.

Summary List

KAESER Pressure maintenance system Model DHS4.0 25G G1" PS16

3,123.75 € 3123.75 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 32G G1 1/4" PS16

3,165.40 € 3165.4 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 350 DN350 PS10

11,947.60 € 11947.6 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 40G G1 1/2" PS16

3,290.35 € 3290.35 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 50 DN50 PS16

3,337.95 € 3337.9500000000003 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 50G G2" PS16

3,445.05 € 3445.05 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 65 DN65 PS16

3,439.10 € 3439.1 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 65G G2 1/2" PS16

3,891.30 € 3891.3 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 80 DN80 PS16

3,456.95 € 3456.9500000000003 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 20G G3/4" PS16

3,076.15 € 3076.15 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 300 DN300 PS10

8,752.45 € 8752.45 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 150 DN150 PS16

4,379.20 € 4379.2 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 125 DN125 PS16

4,004.35 € 4004.35 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER Pressure maintenance system Model DHS4.0 100 DN100 PS16

3,593.80 € 3593.8 EUR VAT Included

Delivery time: 3 - 5 working days

KAESER DHS 4.0 Pressure Maintenance System – Which model is right for your system?

After a shutdown, the compressed air system is depressurized. When the compressors are restarted, there is no resistance from system pressure—the compressed air flows through the treatment components at too high a velocity. A DHS 4.0 series pressure-maintaining system prevents this: It maintains the required minimum pressure until the system has reached operating pressure again.

DHS 4.0 with ball valve – threaded connection G 3/4" to G 2 1/2"

The G models are installed directly into piping with threaded connections. A high-pressure kit for operation up to 63 bar is available as an option.

ModelConnectionMax. OverpressureDimensions (W × D × H)Mass
DHS 4.0 20GG 3/4"16 bar220×234×300 mm5.9 kg
DHS 4.0 25GG 1"16 bar220 × 244 × 335 mm7.8 kg
DHS 4.0 32GG 1 1/4"16 bar220 × 244 × 346 mm9.6 kg
DHS 4.0 40GG 1 1/2"16 bar220×249×378 mm10.4 kg
DHS 4.0 50GG 2"16 bar299 × 256 × 417 mm11.4 kg
DHS 4.0 65GG 2 1/2"16 bar349 × 264 × 460 mm17.8 kg

DHS 4.0 with intermediate flap – flange connection DN 50 to DN 150

The DN variants are installed directly into the piping using a flange connection and are suitable for larger nominal diameters.

ModelConnectionMax. OverpressureDimensions (W × D × H)Mass
DHS 4.0 50DN 5016 bar220 × 244 × 427 mm9.6 kg
DHS 4.0 65DN 6516 bar258 × 259 × 459 mm11.1 kg
DHS 4.0 80DN 8016 bar258 × 268 × 489 mm12.6 kg
DHS 4.0 100DN 10016 bar299 × 290 × 545 mm16.7 kg
DHS 4.0 125DN 12516 bar348 × 320 × 597 mm23.7 kg
DHS 4.0 150DN 15016 bar397 × 342 × 645 mm28.9 kg

Ball valve or intermediate damper?

The selection depends on the existing piping: Piping with threaded connections (typically up to G 2 1/2") requires a model with a ball valve (G Series). For flanged connections starting at DN 50, the version with an intermediate butterfly valve is used. Both versions use the same spring-loaded pneumatic rotary actuator and the same electronic control unit—they differ only in the shut-off element and the connection type.

Integration into the compressed air station

The DHS 4.0 is installed between the compressor and the first treatment stage. This way, it protects Refrigeration Dryers, Compressed Air Filters and protects downstream equipment from uncontrolled overcurrent. The system can be integrated into the higher-level SIGMA AIR MANAGER 4.0 control system via the standard SIGMA NETWORK interface. For larger connection sizes starting at DN 200, we would be happy to provide you with personalized advice.

Nick Bender