KAESER screw compressor SXC 3-11 SC3 incl. refrigeration dryer and receiver
Compact complete compressed air station with refrigeration dryer and 215 l tank. 0.26 m³/min | max. 11 bar | 2.2 kW | SIGMA CONTROL 3 S | 0.62 m² footprint
KAESER SXC 3-11 SC3: The compact compressed air station with max. 11 bar
The SXC series was developed by KAESER developed specifically for tough everyday use in trade workshops. The SXC 3-11 SC3 is KAESER's entry-level screw compressor. With its 2.2 kW motor power, this compact compressed air station delivers a reliable 0.26 m³/min (260 l/min) at an operating pressure of 10 bar and a maximum overpressure of 11 bar. Where conventional metal housings quickly become dented or scratched in confined workshops, the SXC impresses with a rotationally sintered, double-walled PE hood - virtually indestructible, corrosion-free and extremely sound-insulating. With a sound pressure level of just 68 dB(A), it is pleasantly quiet.
As a ready-to-use complete system, the SXC 3-11 combines a screw compressor with the highly efficient SIGMA PROFILE, the integrated CT 4 refrigeration dryer (pressure dew point +6 °C) and a 215-liter compressed air tank on a footprint of just 0.62 m². The IE3 premium efficiency motor with 2.2 kW rated power and the maintenance-free V-ribbed belt drive ensure energy-efficient and reliable operation. The Sigma Control 3 S touch control enables intuitive monitoring of all operating parameters and controls the efficient start-stop regulation. Installation is extremely simple: connect the power supply and compressed air line - done.
Recommended use: Ideal for automotive workshops, locksmiths and production plants that require increased operating pressure for compressed air tools, sandblasting or longer pipe runs.
Accessories & documentation: Suitable filters and oil/water separators can be found in the Accessories section. All technical data, data sheets and operating instructions are available for download in the respective tabs.
Note: This dryer series contains fluorinated greenhouse gas. All models contain the refrigerant R-513A (GWP 631).
Alternative: Do you need a solution for continuous industrial use? You can find the right counterpart from the KAESER Aircenter series below under "Alternative products".
| Max. overpressure (bar) | 11 |
| Volume flow at overpressure (m³/min) | 0,26 |
| Rated power drive motor (kW) | 2,2 |
| Drive motor efficiency class | IE3 |
| Permissible pressure loss cooling channel (Pa) | 20 |
| Max. usable warm air volume (m³/h) | 850 |
| Electrical supply | 400 V / 3 Ph / 50 Hz |
| Full load current | 5 A |
| Fuse: Max current | 10 A |
| Width (mm) | 620 |
| Depth (mm) | 980 |
| Height (mm) | 1480 |
| Weight (kg) | 285 |
| Volume of compressed air tank (litres) | 215 |
| Compressed air connection | G 3/4 |
| Sound pressure level (dbA) | 68 |
| Refrigeration dryer power consumption (kW) | 0,18 |
| Refrigeration dryer pressure dew point (°C) | 6 |
| Refrigeration dryer pressure loss (bar) | 0,02 |
| Refrigerant | R-513A |
| Refrigerant charge (kg) | 0,17 |
| CO2 equivalent (tonnes) | 0,11 |
| Global warming potential GWP | 631 |
| Model range - Screw compressors | SXC | 2.2 - 5.5 kW | Trades |
| Refrigeration dryer option | YES |
| Max. overpressure (bar) | 11 |
| Volume flow at overpressure (m³/min) | 0,26 |
| Rated power drive motor (kW) | 2,2 |
| Drive motor efficiency class | IE3 |
| Permissible pressure loss cooling channel (Pa) | 30 |
| Max. usable warm air volume (m³/h) | 1000 |
| Max. usable heat output "warm air" (kW) | 2,7 |
| Electrical supply | 400 V / 3 Ph / 50 Hz |
| Full load current | 6 A |
| Fuse: Max current | 10 A |
| Width (mm) | 590 |
| Depth (mm) | 1090 |
| Height (mm) | 1560 |
| Weight (kg) | 285 |
| Compressed air connection | G 3/4 |
| Sound pressure level (dbA) | 59 |
| Refrigeration dryer power consumption (kW) | 0,18 |
| Refrigeration dryer pressure dew point (°C) | 3 |
| Permissible pressure loss cooling channel (Pa) | 0,02 |
| Refrigerant | R-513A |
| Refrigerant charge (kg) | 0,17 |
| CO2 equivalent (tonnes) | 0,11 |
| Global warming potential GWP | 631 |
| Max. overpressure (bar) | 11 |
| Volume flow at overpressure (m³/min) | 0,26 |
| Rated power drive motor (kW) | 2,2 |
| Drive motor efficiency class | IE3 |
| Permissible pressure loss cooling channel (Pa) | 30 |
| Max. usable warm air volume (m³/h) | 1000 |
| Max. usable heat output "warm air" (kW) | 2,7 |
| Electrical supply | 400 V / 3 Ph / 50 Hz |
| Full load current | 6 A |
| Fuse: Max current | 10 A |
| Width (mm) | 590 |
| Depth (mm) | 1090 |
| Height (mm) | 1560 |
| Weight (kg) | 285 |
| Compressed air connection | G 3/4 |
| Sound pressure level (dbA) | 59 |
| Refrigeration dryer power consumption (kW) | 0,18 |
| Refrigeration dryer pressure dew point (°C) | 3 |
| Permissible pressure loss cooling channel (Pa) | 0,02 |
| Refrigerant | R-513A |
| Refrigerant charge (kg) | 0,17 |
| CO2 equivalent (tonnes) | 0,11 |
| Global warming potential GWP | 631 |